Smoke alarms go in every bedroom, outside each sleeping area, and on every level including the basement. Carbon monoxide alarms go outside each sleeping area, close to the bedrooms, and in any bedroom with a fuel-burning appliance; Colorado law puts them within 15 feet of each bedroom's entrance. Mount smoke alarms on the ceiling when you can, keep them away from cooking appliances, interconnect them so one sounds all, and replace smoke alarms every 10 years.
“…they are remarkably responsive to questions and needs during a project.”
| Location | Smoke alarm | CO alarm |
|---|---|---|
| Each bedroom | Yes | If the bedroom has a fuel-burning appliance |
| Hallway outside bedrooms | Yes | Yes, close to the bedrooms (within 15 feet of each bedroom entrance under Colorado law) |
| Every level, including the basement | Yes | Recommended where there are fuel-burning appliances |
| Near the kitchen | At least 10 to 20 feet from a cooking appliance for ionization alarms, depending on the model; 6 feet for photoelectric | Follow the alarm's instructions |
| Garage | Not usually; heat alarms are an option | Not in the garage itself; CO alarms go in the living space near the door |
Sources: International Residential Code sections on smoke and CO alarms, and Colorado law on CO alarms (CRS 38-45). For what the law requires and when, see Smoke and CO alarm requirements for Colorado homes.
Smoke rises, so ceiling mounting is preferred. If you must mount on a wall, place the alarm 4 to 12 inches below the ceiling.
Ionization alarms go at least 20 feet from a cooking appliance, or 10 feet if they have a silence button; photoelectric alarms go at least 6 feet away. Keep alarms away from bathroom doors where steam sets them off.
Air from supply vents and ceiling fans can push smoke away from the alarm or cause false alarms.
Follow the alarm's instructions for sloped ceilings, which usually means near, but not at, the peak.
When one alarm senses smoke, every alarm in the house sounds. Hardwired interconnected alarms with battery backup are the norm for new work; wireless interconnected alarms fit existing homes.
Replace smoke alarms 10 years after the date on the back. CO alarms have their own end-of-life date from the manufacturer.
| Hardwired interconnected | Wireless interconnected | Battery-only standalone | |
|---|---|---|---|
| Power | House wiring with battery backup | Sealed or replaceable batteries | Batteries |
| Interconnection | Wired between alarms | Wireless between alarms | None |
| Best for | New construction, remodels, replacing existing hardwired alarms | Finished homes without wiring | Temporary or supplemental use |
On every visit, a licensed Eggers electrician handles the job you called about and runs our full Safety Inspection. There's a $89 service charge — and it is credited toward your job if you move forward.
The 8 points: electrical panel, main grounding & bonding, GFCI protection, smoke & CO detectors, outlets & switches, visible wiring, exterior electrical, and whole-home surge protection. Each one is marked Pass or Needs Attention.
Chirps, red lights and end of life
Fix flagged electrical items before closing
Catch unsafe components early
What a symptom means and what's safe to check
Replace old wiring and protect what you plug in

Questions? Call 970-669-1883 or email info@eggerselectric.com.
Serving Loveland, Fort Collins and Northern Colorado · 970-669-1883
Written by the Eggers Electric team
In every bedroom, outside each sleeping area, and on every level including the basement, mounted on the ceiling when possible.
Outside each sleeping area, close to the bedrooms, and in any bedroom with a fuel-burning appliance. Colorado law requires them within 15 feet of each bedroom's entrance in the homes it covers.
Ionization alarms at least 20 feet from a cooking appliance, or 10 feet with a silence button; photoelectric alarms at least 6 feet.
For new construction and many remodels, yes. Interconnected alarms all sound when one detects smoke. Wireless interconnected alarms make it practical in existing homes.
Every 10 years from the date on the back. CO alarms follow the manufacturer's end-of-life date.
Usually a low battery or an alarm at end of life. See smoke detector chirping.
Through Dec 17: donate food for the Larimer County Food Bank and we’ll waive the $89.
★★★★★ Google 4.9 · 400+ reviews
Need an electrician?
On every visit, a licensed Eggers electrician handles the job you called about and runs our full Safety Inspection. There's a $89 service charge — and it is credited toward your job if you move forward.
Through Dec 17: bring non-perishable food for the Larimer County Food Bank and we’ll waive the $89 service charge.
Schedule Serviceor call 970-669-1883 · Call 7 days, 7am–8pm
Ask a question
Send us a message and we’ll follow up. Need help now? Call 970-669-1883.