Most full-size hot tubs need a dedicated 240-volt circuit with GFCI protection and a maintenance disconnect within sight of the tub, at least 5 feet from the water unless there's a barrier. Some smaller "plug-and-play" tubs run on 120 volts; a listed packaged unit can plug into a GFCI-protected outlet with a cord no longer than 15 feet. Metal parts near the tub get bonded, and switches and lights have clearance rules too. The tub's manual sets the circuit size; the permit and inspection confirm the rest.
“…they are remarkably responsive to questions and needs during a project.”
| 120-volt plug-in tub | 240-volt hardwired tub | |
|---|---|---|
| Circuit | A dedicated, GFCI-protected outlet sized to the tub | A dedicated 240-volt circuit sized to the tub's manual |
| Connection | Cord no longer than 15 feet, for a listed packaged unit | Wired through a GFCI-protected disconnect to the tub |
| Heating | Often can't heat and run jets at full power at the same time | Heats and runs jets together |
| Best for | Smaller tubs, mild use, simpler installs | Most full-size tubs and year-round Colorado use |
| Permit | Yes, for a new outlet circuit | Yes |
Sized from the tub's installation manual. Nothing else shares it.
Ground-fault protection on the tub's supply, usually in the disconnect. A listed unit with built-in GFCI protection is the exception the code allows.
A readily accessible disconnect within sight of the tub, at least 5 feet from the inside wall of the tub unless a permanent barrier separates them. It lets you or a technician shut power off at the tub.
Metal parts within 5 feet of the tub, such as railings, fixtures and equipment, are bonded so they stay at the same voltage. A listed packaged spa may have its bonding built in.
Wall switches go at least 5 feet from the inside wall of the tub. Lights above or near the tub have height and protection rules.
A 240-volt tub is a big load. A load calculation shows whether your panel can carry it.
On every visit, a licensed Eggers electrician handles the job you called about and runs our full Safety Inspection. There's a $89 service charge — and it is credited toward your job if you move forward.
The 8 points: electrical panel, main grounding & bonding, GFCI protection, smoke & CO detectors, outlets & switches, visible wiring, exterior electrical, and whole-home surge protection. Each one is marked Pass or Needs Attention.

Questions? Call 970-669-1883 or email info@eggerselectric.com.
Serving Loveland, Fort Collins and Northern Colorado · 970-669-1883
Written by the Eggers Electric team
Yes. Whether it's a 120-volt plug-in or a 240-volt hardwired tub, it gets its own circuit sized from the tub's manual.
At least 5 feet from the inside wall of the tub, within sight of it and readily accessible, unless a permanent barrier separates them.
Yes. The tub's supply needs ground-fault protection, usually provided in the disconnect. A listed unit with built-in GFCI protection is the exception.
Only a listed 120-volt packaged tub, into a GFCI-protected outlet on its own circuit, with a cord no longer than 15 feet. Never use an extension cord.
Yes. Hot tub circuits need an electrical permit and inspection in the towns and counties we serve. We pull it.
Yes, ideally. Having the circuit and disconnect ready means the tub can be filled and powered the day it arrives.
Through Dec 17: donate food for the Larimer County Food Bank and we’ll waive the $89.
★★★★★ Google 4.9 · 400+ reviews
Need an electrician?
On every visit, a licensed Eggers electrician handles the job you called about and runs our full Safety Inspection. There's a $89 service charge — and it is credited toward your job if you move forward.
Through Dec 17: bring non-perishable food for the Larimer County Food Bank and we’ll waive the $89 service charge.
Schedule Serviceor call 970-669-1883 · Call 7 days, 7am–8pm
Ask a question
Send us a message and we’ll follow up. Need help now? Call 970-669-1883.